Virgil Creek Synoptic Monitoring Event on June 07, 2021, under Base Flow conditions
Virgil Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Remarks | Location |
---|---|---|---|---|
Dryden Lake Outlet | Temperature | 20.0 C | Field | |
Chloride | 17.3 mg/L | Lab | ||
Solids, Total Suspended | 24.5 mg/L | Lab | ||
Total Phosphorus (as P) | 62.1 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.14 mg/L | Lab | ||
Specific Conductance | 228.0 uS/cm | Lab | ||
Turbidity | 21.0 NTU | Field blank failed, results may be biased high | Lab | |
E. Coli | 60.0 Colonies/100 ml | Lab | ||
Soluble Reactive Phosphorus (as P) | 5.82 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Spring House Bridge | Chloride | 35.7 mg/L | Lab | |
Soluble Reactive Phosphorus (as P) | 14.2 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 6.25 mg/L | Lab | ||
E. Coli | 120.0 Colonies/100 ml | Lab | ||
Total Phosphorus (as P) | 24.3 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.57 mg/L | Lab | ||
Turbidity | 4.9 NTU | Field blank failed, results may be biased high | Lab | |
Temperature | 16.0 C | Field | ||
Specific Conductance | 368.0 uS/cm | Lab | ||
Dryden Lake Park | Chloride | 15.1 mg/L | Lab | |
Solids, Total Suspended | 12.8 mg/L | Lab | ||
Total Phosphorus (as P) | 38.5 ug/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 8.61 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Turbidity | 12.0 NTU | Field blank failed, results may be biased high | Lab | |
Nitrate-+Nitrite-Nitrogen (as N) | 0.08 mg/L | Lab | ||
Temperature | 20.0 C | Field | ||
Specific Conductance | 207.0 uS/cm | Lab | ||
E. Coli | 20.0 Colonies/100 ml | Lab | ||
Dryden Lake Inlet | Chloride | 36.4 mg/L | Lab | |
Solids, Total Suspended | 0.63 mg/L | non-detect | Lab | |
Total Phosphorus (as P) | 29.0 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 5.52 mg/L | Lab | ||
E. Coli | 2620.0 Colonies/100 ml | Lab | ||
Temperature | 8.0 C | Field | ||
Specific Conductance | 502.0 uS/cm | Lab | ||
Turbidity | 0.65 NTU | Field blank failed, results may be biased high | Lab | |
Soluble Reactive Phosphorus (as P) | 14.7 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Virgil Creek Freeville | Kjeldahl Nitrogen, Total (as N) | 0.4 mg/L | estimate | Lab |
Specific Conductance | 406.0 uS/cm | Lab | ||
Chloride | 45.1 mg/L | Lab | ||
Solids, Total Suspended | 6.5 mg/L | Lab | ||
Total Phosphorus (as P) | 25.9 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.45 mg/L | Lab | ||
E. Coli | 120.0 Colonies/100 ml | Lab | ||
Temperature | 17.0 C | Field | ||
Soluble Reactive Phosphorus (as P) | 7.67 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Turbidity | 7.3 NTU | Field blank failed, results may be biased high | Lab | |
Virgil Creek Road | Chloride | 44.4 mg/L | Lab | |
Solids, Total Suspended | 8.25 mg/L | Lab | ||
Total Phosphorus (as P) | 20.7 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.94 mg/L | Lab | ||
E. Coli | 200.0 Colonies/100 ml | Lab | ||
Temperature | 15.0 C | Field | ||
Soluble Reactive Phosphorus (as P) | 4.86 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Specific Conductance | 410.0 uS/cm | Lab | ||
Turbidity | 8.1 NTU | Field blank failed, results may be biased high | Lab |