Canoga Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Canoga Creek North Branch Soluble Reactive Phosphorus (as P) 99.6 ug/L Exceeded 15 min. holding time for filtration Lab
Temperature 16.0 C Field
Chloride 27.5 mg/L Lab
Solids, Total Suspended 25.3 mg/L Lab
Total Phosphorus (as P) 191.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.04 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.94 mg/L Lab
E. Coli 7750.0 Colonies/100 ml Lab
Specific Conductance 844.0 uS/cm Lab
Turbidity 60.0 NTU Field blank failed, results may be biased high Lab
Canoga Creek South Branch Temperature 20.0 C Field
Chloride 21.6 mg/L Lab
Solids, Total Suspended 210.0 mg/L Lab
Total Phosphorus (as P) 908.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 4.04 mg/L Lab
E. Coli 13200.0 Colonies/100 ml Lab
Specific Conductance 461.0 uS/cm Lab
Kjeldahl Nitrogen, Total (as N) 2.86 mg/L Result may be biased low when Nitrate+Nitrite Nitrogen (as N) > 4 mg/L Lab
Soluble Reactive Phosphorus (as P) 127.0 ug/L Exceeded 15 min. holding time for filtration Lab
Turbidity 333.0 NTU Field blank failed, results may be biased high Lab