Notes: Event Time = Time of sampling (Eastern Time) at stream mouth (Taughannock Falls); Taughannock Falls (TGF)- Light Fog, Light breeze upstream from lake on surface; Bolter Creek at Cook Rd. (TGCR)- Sample collected downstream side of bridge, but upstream of cattle crossing "alley" fence. Access to creek is very steep and the less steep side, downstream, I discovered is laced with HOT electric fencing. Collecting w/bucket may not be feasible due to creek depth.; Bolter Creek at Runoff/Creek Convergence (TGCV)- Sample collected downstream of where runoff previously converged w/creek when water was higher this spring. Runoff was not observed actively entering stream; Bolter Creek at Blow Down at Site (TGBD)- Beef cattle operation immediately upstream, overwinters on floodplain and has year round access to creek
Taughannock Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Bolter Creek at Blow Down at Site
(TGBD)
Total Phosphorus (as P) 5.72 ug/L Lab
Soluble Reactive Phosphorus (as P) 5.64 ug/L Exceeded 15 min. holding time for filtration Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.02 mg/L Lab
E. Coli 220.0 Colonies/100 ml Lab
Bolter Creek at Cook Rd.
(TGCR)
Total Phosphorus (as P) 14.0 ug/L Lab
Soluble Reactive Phosphorus (as P) 11.7 ug/L Exceeded 15 min. holding time for filtration Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.22 mg/L Lab
E. Coli 20.0 Colonies/100 ml Lab
Bolter Creek at Runoff/Creek Convergence
(TGCV)
Total Phosphorus (as P) 8.22 ug/L Lab
Soluble Reactive Phosphorus (as P) 9.08 ug/L Exceeded 15 min. holding time for filtration Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.04 mg/L Lab
E. Coli 10.0 Colonies/100 ml non-detect Lab