Notes: Event Time= Time of Sampling (Eastern Time) at North Branch Mouth (CANB).
Canoga Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Canoga Creek South Branch
(CASB)
Turbidity 7.3 NTU Lab
Total Phosphorus (as P) 50.9 ug/L Lab
Temperature 9.0 C Field
Specific Conductance 782.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 12.8 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 2.0 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.58 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.3 mg/L Estimated Lab
Hydrogen Ion (pH) 8.25 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Hardness, Total 368.0 mg CaCO3/L Lab
E. Coli 60.0 Colonies/100 ml Lab
Chloride 40.1 mg/L Lab
Alkalinity 207.0 mg CaCO3/L Sample Collected with head space Lab
Canoga Creek North Branch
(CANB)
Turbidity 6.0 NTU Lab
Total Phosphorus (as P) 44.6 ug/L Lab
Temperature 10.0 C Field
Specific Conductance 1387.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 13.8 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 1.0 mg/L non-detect Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.14 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.25 mg/L Estimated Lab
Hydrogen Ion (pH) 7.25 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Hardness, Total 763.0 mg CaCO3/L Lab
E. Coli 60.0 Colonies/100 ml Lab
Chloride 41.4 mg/L Lab
Alkalinity 235.0 mg CaCO3/L Sample Collected with head space Lab