Notes:
Fall Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Lafayette Road Culvert
(LRC)
Turbidity 0.67 NTU Lab
Total Phosphorus (as P) 107.0 ug/L Lab
Total Coliform 8500.0 Colonies/100 ml Lab
Specific Conductance 344.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 125.0 ug/L Blank > 10%; Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 2.5 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 8.99 mg/L Lab
Hydrogen Ion (pH) 7.75 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Hardness, Total 215.0 mg CaCO3/L Lab
E. Coli 1040.0 Colonies/100 ml Lab
Chloride 24.5 mg/L Lab
Alkalinity 156.0 mg CaCO3/L Sample collected with head space Lab
Dryden and Freeville Sewage Treatment Plant Outfall
(FCOF)
Turbidity 1.74 NTU Lab
Total Phosphorus (as P) 824.0 ug/L Lab
Total Coliform 10500.0 Colonies/100 ml Lab
Specific Conductance 894.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 600.0 ug/L Estimated; Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 1.75 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.64 mg/L Lab
Hydrogen Ion (pH) 7.25 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Hardness, Total 249.0 mg CaCO3/L Lab
E. Coli 40.0 Colonies/100 ml Lab
Chloride 135.0 mg/L Lab
Alkalinity 216.0 mg CaCO3/L Sample collected with head space Lab